Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Main subject
Language
Document Type
Year range
1.
Ann Transl Med ; 11(6): 253, 2023 Mar 31.
Article in English | MEDLINE | ID: covidwho-2229349

ABSTRACT

Background: Spontaneous breathing efforts during mechanical ventilation are a widely accepted weaning approach for acute respiratory distress syndrome (ARDS) patients. These efforts can be too vigorous, possibly inflicting lung and diaphragm damage. Higher positive end expiratory pressure (PEEP) levels can be used to lower the magnitude of vigorous breathing efforts. Nevertheless, PEEP titrating tools are lacking in spontaneous mechanical ventilation (SMV). Therefore, the aim is to develop an electrical impedance tomography (EIT) algorithm for quantifying regional lung mechanics independent from a stable plateau pressure phase based on regional peak flow (RPF) by EIT, which is hypothetically applicable in SMV and to validate this algorithm in patients on controlled mechanical ventilation (CMV). Methods: The RPF algorithm quantifies a cumulative overdistension (ODRPF) and collapse (CLRPF) rate and is validated in a prospective cohort of mechanically ventilated severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) patients on CMV. ODRPF and CLRPF are compared with compliance-based cumulative overdistension (ODP500) and collapse (CLP500) rates from the Pulmovista 500 EIT device at multiple PEEP levels (PEEP 10 cmH2O to PEEP 24 cmH2O) in EIT measurements from CMV patients by linear mixed models, Bland-Altman analysis and intraclass correlation coefficient (ICC). Results: Seventy-eight patients were included. Linear mixed models revealed an association between ODRPF and ODP500 of 1.02 (0.98-1.07, P<0.001) and between CLRPF and CLP500 of 0.93 (0.80-1.05, P<0.001). ICC values ranged from 0.78 to 0.86 (P<0.001) for ODRPF and ODP500 and from 0.70 to 0.85 (P<0.001) for CLRPF and CLP500 (PEEP 10 to PEEP 24). The mean bias between ODRPF and ODP500 in these PEEP levels ranged from 0.80% to 4.19% and from -1.31% to 0.13% between CLRPF and CLP500. Conclusions: A RPF approach for quantifying regional lung mechanics showed a moderate to good agreement in coronavirus disease 2019 (COVID-19) related ARDS patients on CMV compared to the compliance-based approach. This, in addition to being independent of a plateau pressure phase, indicates that the RPF approach is a valid method to explore for quantifying regional lung mechanics in SMV.

2.
Sci Rep ; 12(1): 14517, 2022 08 25.
Article in English | MEDLINE | ID: covidwho-2016838

ABSTRACT

Patients with SARS-CoV-2 infection present with different lung compliance and progression of disease differs. Measures of lung mechanics in SARS-CoV-2 patients may unravel different pathophysiologic mechanisms during mechanical ventilation. The objective of this prospective observational study is to describe whether Electrical Impedance Tomography (EIT) guided positive end-expiratory pressure (PEEP) levels unravel changes in EIT-derived parameters over time and whether the changes differ between survivors and non-survivors. Serial EIT-measurements of alveolar overdistension, collapse, and compliance change in ventilated SARS-CoV-2 patients were analysed. In 80 out of 94 patients, we took 283 EIT measurements (93 from day 1-3 after intubation, 66 from day 4-6, and 124 from day 7 and beyond). Fifty-one patients (64%) survived the ICU. At admission mean PaO2/FiO2-ratio was 184.3 (SD 61.4) vs. 151.3 (SD 54.4) mmHg, (p = 0.017) and PEEP was 11.8 (SD 2.8) cmH2O vs. 11.3 (SD 3.4) cmH2O, (p = 0.475), for ICU survivors and non-survivors. At day 1-3, compliance was ~ 55 mL/cmH2O vs. ~ 45 mL/cmH2O in survivors vs. non-survivors. The intersection of overdistension and collapse curves appeared similar at a PEEP of ~ 12-13 cmH2O. At day 4-6 compliance changed to ~ 50 mL/cmH2O vs. ~ 38 mL/cmH2O. At day 7 and beyond, compliance was ~ 38 mL/cmH2O with the intersection at a PEEP of ~ 9 cmH2O vs. ~ 25 mL/cmH2O with overdistension intersecting at collapse curves at a PEEP of ~ 7 cmH2O. Surviving SARS-CoV-2 patients show more favourable EIT-derived parameters and a higher compliance compared to non-survivors over time. This knowledge is valuable for discovering the different groups.


Subject(s)
COVID-19 , Electric Impedance , Humans , Positive-Pressure Respiration/methods , SARS-CoV-2 , Tomography/methods , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL